{"resourceId":"arxiv-2611-31960-typical-query-energy-underestimates-university-ai-electricity-sullee-20261124","versions":[{"version":"external-3f3c6fa05284dae37cd3f382db83339439fd2d7e48b4c343868224fe941080cd","resource":{"id":"arxiv-2611-31960-typical-query-energy-underestimates-university-ai-electricity-sullee-20261124","title":"Griffith University preprint: multiplying a 'typical' energy-per-query figure by visible prompts underestimates a university's AI inference electricity about 3.4 times today and about 15 times in a 2030 scenario; agent workflows drive the growth","organization":"Griffith University, Australia (Nathan A. Garland, Ryan F. Heneghan)","sector":"Research enterprise and university operations: AI inference electricity, emissions accounting and sustainability reporting","geography":"Australia (Australian public universities case study); method transferable to U.S. institutions with local inputs","publishedAt":"Submitted to arXiv 24 November 2026 (arXiv 2611.31960, v1, cs.CY); appeared in the cs.CY new listing of Wednesday 25 November 2026","publicationDate":"2026-11-24","eventDate":null,"sourceName":"arXiv (Garland and Heneghan, Griffith University)","sourceLabel":"Garland, N. A., Heneghan, R. F., \"Typical-query energy figures mislead institutional AI electricity demand,\" arXiv:2611.31960, Nov 2026","sourceUrl":"https://arxiv.org/abs/2611.31960","evidenceClass":"academic-research","outcomeClass":"cautionary","topics":["infrastructure","governance-procurement","operating-model"],"finding":"Preprint, not peer reviewed; a modelling study, not measured consumption. The authors' open SULLEE model links token counts, serving hardware and workflow structure to annual institutional electricity, with Monte Carlo uncertainty. Multiplying one 'typical' per-query energy figure by visible user prompts misses two things: energy per task is right-skewed, and each visible prompt can trigger more agent and tool calls. Together these imply an underestimate of about 3.4 times under present-day observed use, rising to about 15 times in a 2030 high-integration scenario. The highest-energy 10% of requests account for about 60% of modelled inference electricity. For a representative 20,000-student Australian university, mean annual AI inference electricity rises from 17.3 MWh (P05-P95 3.1-47.1) under 2026 observed use to up to 287.4 MWh (41.5-830.7) by 2030. Conventional chat is about 87% of modelled electricity in 2026 but about 20% in the 2030 scenario, while agent workflows rise from about 8% to about 78%. The authors note that Monte Carlo sampling of declared priors is not a measured population distribution. Included because it is new (24 Nov) and gives universities a method for AI emissions reporting as agent use grows.","sledRelevance":"Relevant to universities buying enterprise AI services and reporting Scope 3 emissions: it shows per-query figures used in sustainability claims can understate demand several-fold, mostly because of agent workflows. Figures are modelled for Australian universities; U.S. transfer needs local usage, hardware and grid data.","evidence":"Single modelling preprint; abstract, highlights, context, model description, scenario results and Scope 3 discussion read. Outputs depend on assumed hardware, task mix (for example user chat 20-40% of requests) and uptake scenarios; no metered institutional data validate the totals.","architectureImplications":"Agent and tool-call context dominates future inference energy; architecture choices that shrink context and tool loops matter more than chat volume.","governanceImplications":"Sustainability reporting on AI should use task-level, workflow-aware estimates with uncertainty ranges, not a single per-query figure.","securityPrivacyImplications":"Not discussed; the model needs aggregate usage telemetry, which institutions would collect from vendor or gateway logs.","caveats":"Preprint; modelled, not metered; Australian case; assumptions on hardware, task mix and uptake drive results; wide uncertainty ranges.","streamIds":["research"],"roles":{"sales":"Framing point: a university's AI electricity may be several times what single per-query figures suggest. This Griffith University preprint models a 3.4-fold underestimate today and about 15-fold by 2030, driven by agent workflows. Sales teams can raise AI energy accounting with sustainability and IT leaders, but should present it as a modelled Australian case with wide uncertainty ranges, not a measured result, and avoid promising emissions cuts.","engineering":"Framing point: count model calls and tokens, not visible prompts. The SULLEE model attributes growth to agent and tool calls, with the top 10% of requests drawing about 60% of modelled electricity. Pre-sales engineers can propose gateway telemetry capturing tokens, models and workflow fan-out per request, then feed those data into a workflow-aware estimate, while noting the paper's results rest on assumed hardware, task mix and uptake.","delivery":"Framing point: build AI energy reporting on workflow-level data with uncertainty ranges. A delivery team could collect token and agent-call logs from the campus AI gateway, run an open model such as SULLEE with local inputs, and compare with vendor per-query figures. These are proposed steps; the source is a modelling study for Australian universities, so local data must replace its assumptions before any reported total."},"roleDetails":{"sales":{"customerProblem":"Universities reporting AI-related emissions may rely on per-query figures that understate demand as agent use grows.","stakeholders":["Chief sustainability officer","CIO","Facilities and energy manager","Procurement lead"],"discoveryQuestions":["How do you estimate AI electricity or emissions today?","Can you see token and agent-call data from your AI services?","Do vendors give you per-workflow energy data?","Is AI in your Scope 3 reporting?"],"valueHypothesis":"Workflow-aware estimates may give more defensible AI emissions reporting; shown only in a modelled Australian case.","potentialEngagement":"A short assessment of AI usage telemetry and a pilot workflow-aware energy estimate for one academic year.","unsupportedClaims":["Measured campus electricity totals","U.S. figures without local inputs","Emissions reductions from any action","Guaranteed savings"]},"engineering":{"fit":"Fits institutions running an AI gateway or enterprise AI licences with access to usage logs.","architectureIntegration":"Gateway or vendor logs of tokens, model and tool calls per request feed an open bottom-up energy model with Monte Carlo uncertainty.","prerequisites":["Token-level usage logs","Model and hardware assumptions","Local grid emissions factors","Uptake scenarios"],"constraints":["Modelled not metered","Australian case","Vendor hardware data often unavailable","Wide uncertainty ranges"],"security":"Usage telemetry should be aggregated and stripped of user content before modelling; not addressed by the paper.","proofOfValue":["Compare per-query and workflow-aware estimates on local logs","Test sensitivity to hardware and task-mix assumptions","Check against any vendor-provided energy data"]},"delivery":{"work":"Collect AI usage telemetry, run a workflow-aware energy estimate and integrate results into sustainability reporting.","dependencies":["Access to gateway or vendor logs","Sustainability office input","Grid emissions data","Analyst time"],"ownership":"The sustainability office owns reporting; IT owns usage telemetry and the AI gateway.","skillsAdoption":"Sustainability analysts learn token-based accounting; IT staff learn to expose workflow fan-out metrics.","governanceCheckpoints":["Approval of telemetry collection scope","Review of assumptions before publication","Annual update of uptake scenarios"],"acceptanceCriteria":["Proposed: estimate reported with uncertainty range","Proposed: agent-call share of traffic measured","Proposed: comparison with per-query method documented"],"risks":["Assumptions dominating results","Incomplete vendor data","Misreading modelled totals as measured","Privacy concerns over logs"]}},"retrievedAt":"2026-11-25T21:55:41-06:00","enrichedAt":"2026-11-25T21:55:41-06:00","enrichmentBasis":"retrieved source","accessibilityWorkforceImplications":"Sustainability and IT staff need skills to gather token and workflow data and run uncertainty models.","procurementImplications":"Institutions could ask AI vendors for token, model and hardware data per workflow to support Scope 3 reporting; vendor 'typical query' figures may mislead.","operatingModelImplications":"Energy accounting must track agent calls behind each visible prompt, which shifts responsibility toward gateway and platform owners who see that traffic.","peerReview":"preprint","sourceVerification":{"openedUrl":"https://arxiv.org/abs/2611.31960","referenceExcerpt":"Together these imply an underestimate of total inference electricity by a factor of approximately 3.4 under present-day observed use","promptVersion":"sled-research-v4.0","model":null,"basis":"agent-reported inspection"}}}]}