{"resourceId":"netapp-advisory-ntap-20261120-0002-linux-kernel-cve-2026-53006-bmc-sp-eseries-ontap-select-deploy-20261120","versions":[{"version":"external-d01b6dd66181fbf2703f6891bf011b41fd0ace20c3e62cab9d7d5d0bfac43de5","resource":{"id":"netapp-advisory-ntap-20261120-0002-linux-kernel-cve-2026-53006-bmc-sp-eseries-ontap-select-deploy-20261120","title":"NetApp advisory NTAP-20261120-0002: Linux kernel flaw CVE-2026-53006 affects storage controller BMCs and service processors, E-Series SANtricity and ONTAP Select Deploy; only E-Series has fixes","organization":"NetApp","sector":"Cross-SLED storage owners (state, county, campus and K-12 data centers running AFF/FAS/ASA, E-Series or ONTAP Select)","geography":"Global product advisory","publishedAt":"2026-11-20 (advisory v1.0, Interim)","publicationDate":"2026-11-20","eventDate":"2026-11-20","sourceName":"NetApp Product Security","sourceLabel":"Vendor security advisory (Interim, v1.0)","sourceUrl":"https://security.netapp.com/adv_api/advisory/?limit=60&skip=0&order=desc&sort_by=published_date","evidenceClass":"vendor-claim","outcomeClass":"cautionary","topics":["data-security","infrastructure"],"finding":"NetApp published Interim advisory NTAP-20261120-0002 (v1.0, 20 Nov) for CVE-2026-53006, a Linux kernel flaw in versions 4.4 through 7.0.9 that could lead to information disclosure, data modification or denial of service. NetApp scores it CVSS 3.1 AV:N/AC:L/PR:N/UI:N with high confidentiality, integrity and availability impact, and marks exploitation Public. Affected: BMCs for AFF/ASA/FAS A50/A30/A20/C60/C30/FAS50, A320, A800/C800 and C190/A150/A220/FAS2720/FAS2750; the A300/8200 service processor; E-Series SANtricity OS; and the ONTAP Select Deploy utility. Fixes are listed only for SANtricity (11.90R7 and 12.10R1). Five products, including SolidFire/HCI and SnapCenter Plug-in for VMware vSphere, are under investigation. No workaround is given.","sledRelevance":"Interpretation: BMCs and service processors sit on out-of-band management networks in many state, county and campus data centers. This advisory affects common midrange arrays bought by SLED agencies, including the AFF A50 class DeKalb County approved on 10 Nov (archived). Until NetApp ships firmware, the practical control is network isolation of management ports, not patching.","evidence":"Vendor advisory record read from NetApp's public JSON feed: summary, CVSS vector, affected, investigating and fix lists, revision history (v1.0 Initial Public Release, 20261120). No exploit details or timeline for BMC/SP fixes.","architectureImplications":"Out-of-band management (BMC/SP) and the ONTAP Select Deploy VM are separate attack surfaces from ONTAP data paths; inventory them by model.","governanceImplications":"Track the Interim advisory for BMC/SP fixes and record compensating controls for affected models in risk registers.","securityPrivacyImplications":"NetApp's network/no-privilege score differs sharply from Red Hat's and cve.org's local/high-complexity 7.0 score for the same CVE (see Red Hat resource); exposure depends on how the embedded kernel handles IPv6/ICMPv6 on management interfaces.","caveats":"Interim advisory; affected lists may change. NetApp does not explain its network attack vector. Advisory page itself loads via script, so the feed record was read. No SLED-specific incidents reported.","streamIds":["netapp"],"roles":{"sales":"Sales: treat this as a trust conversation, not a pitch. Many SLED customers run the listed AFF, FAS and E-Series models, and the advisory names their management controllers as affected with only E-Series fixed. A partner can offer a short inventory of BMC and service-processor exposure and help the customer track NetApp's fix. Do not claim the flaw is exploited against SLED customers or that any product prevents it; NetApp's 'Public' label and its severity score need independent confirmation before customer messaging.","engineering":"Engineering: map every affected model to its BMC or SP firmware and to the management VLAN it sits on. Check whether IPv6 is enabled on those interfaces, since the upstream bug is in ICMPv6 receive handling. Apply SANtricity 11.90R7 or 12.10R1 for E-Series. For AFF/FAS BMCs and the A300/8200 SP, restrict management access to jump hosts, and confirm ONTAP Select Deploy is not reachable from user networks. Reconcile NetApp's network vector with Red Hat's local scoring before setting priority.","delivery":"Delivery: run a time-boxed exposure review: build the asset list, confirm management-network isolation, schedule E-Series upgrades in maintenance windows, and set a watch on the advisory for BMC/SP firmware. Record compensating controls and owners in the risk register. Proposed acceptance: every affected device inventoried, management access limited to named admin hosts, E-Series on a fixed release. Risks include firmware upgrades that need controller reboots and investigating products moving to affected later."},"roleDetails":{"sales":{"customerProblem":"SLED storage owners have an unpatched kernel flaw in array management controllers with Public exploitation status.","stakeholders":["CISO","Infrastructure manager","Storage administrator","Network operations lead"],"discoveryQuestions":["Which AFF/FAS/ASA and E-Series models do you run, and on which firmware?","Are BMC and SP ports on an isolated management network?","Is IPv6 enabled on management interfaces?","Who tracks NetApp advisories and how quickly are they triaged?"],"valueHypothesis":"A bounded exposure review may shorten the window between disclosure and compensating control; no measured risk reduction is available.","potentialEngagement":"A fixed-scope BMC/SP exposure inventory and segmentation check for listed models, plus E-Series upgrade planning.","unsupportedClaims":["No evidence of exploitation against SLED customers.","NetApp's 9.8-equivalent vector is not confirmed by Red Hat or cve.org scoring.","No fix date for BMC/SP firmware.","No claim that any product blocks the flaw."]},"engineering":{"fit":"Directly relevant to SLED data centers running listed NetApp models.","architectureIntegration":"Affects out-of-band management controllers, E-Series controller OS and the ONTAP Select Deploy VM, not ONTAP data serving.","prerequisites":["Hardware model inventory","Management network diagram","Current SANtricity version","Support site access for downloads"],"constraints":["BMC/SP fixes not yet published","Controller reboots for E-Series upgrades","Some products still under investigation","Air-gapped sites need offline firmware staging"],"security":"Limit BMC/SP and Deploy access to admin jump hosts; consider disabling IPv6 on management ports where supported, after vendor guidance.","proofOfValue":["Confirm which deployed models appear in the affected list","Verify management ports are unreachable from user and guest networks","Test SANtricity upgrade in a non-production pair where available","Re-check the advisory for revised affected lists"]},"delivery":{"work":"Inventory, isolate and patch: exposure review, E-Series upgrades, advisory watch for BMC/SP firmware.","dependencies":["NetApp firmware release","Maintenance windows","Network team for ACL changes","Change advisory board"],"ownership":"Agency infrastructure or storage operations lead, with security office oversight.","skillsAdoption":"Storage admins need BMC/SP firmware procedures; network staff need management-VLAN ACL review.","governanceCheckpoints":["Risk acceptance for unpatched BMC/SP","Change approval for E-Series upgrades","Post-change verification"],"acceptanceCriteria":["All affected devices inventoried within one week (proposal)","Management access limited to named admin hosts (proposal)","E-Series on 11.90R7 or 12.10R1 (proposal)"],"risks":["Firmware upgrade disruption","Investigating products become affected","Severity over- or under-estimated","Shadow management access paths"]}},"retrievedAt":"2026-11-21T04:18:56Z","enrichedAt":"2026-11-21T04:23:37Z","enrichmentBasis":"retrieved source","accessibilityWorkforceImplications":"No accessibility or workforce content.","procurementImplications":"Agencies with support contracts get firmware through NetApp; no procurement action, but contract terms for timely firmware patches matter.","operatingModelImplications":"Storage and network teams must jointly confirm management-network segmentation and IPv6 exposure for listed models.","sourceVerification":{"openedUrl":"https://security.netapp.com/adv_api/advisory/?limit=60&skip=0&order=desc&sort_by=published_date","referenceExcerpt":"could lead to disclosure of sensitive information, addition or modification of data or Denial of Service (DoS)","promptVersion":"sled-research-v4.0","model":null,"basis":"agent-reported inspection"}}}]}