{"resourceId":"tomshardware-vast-sc26-petabyte-ssd-raid-simulation-20261120","versions":[{"version":"external-cc24e8337e54999252967d42fa34fb4a110fc64bb67f88fe1c871f35a62ecd55","resource":{"id":"tomshardware-vast-sc26-petabyte-ssd-raid-simulation-20261120","title":"Tom's Hardware: VAST's SC26 simulation says enclosure-local RAID fails with petabyte SSDs; VAST concedes its triplicated metadata is the weakest link","organization":"VAST Data (presenter) / Tom's Hardware (reporting)","sector":"Research computing and large-scale AI storage (vendor technical claim)","geography":"United States (SC26, Chicago); applies globally","publishedAt":"2026-11-20","publicationDate":"2026-11-20","eventDate":null,"sourceName":"Tom's Hardware","sourceLabel":"Trade-press news analysis of a vendor conference talk","sourceUrl":"https://www.tomshardware.com/pc-components/ssds/vast-data-says-petabyte-ssds-will-outgrow-raid-in-todays-parallel-file-systems-simulation-of-a-900-pb-system-puts-data-loss-odds-at-1-in-11-over-10-years","evidenceClass":"vendor-claim","outcomeClass":"emerging","topics":["infrastructure","governance-procurement"],"finding":"At SC26 VAST presented a simulation of a 900 PB flash system arguing that petabyte-class SSDs will make enclosure-local declustered RAID unsafe (1 in 11 odds of data loss over 10 years) and that system-wide erasure coding with at least three parity strips is the minimum; VAST claims about 1 in 62 billion for its own undisclosed scheme. The same talk concedes VAST's three-copy metadata is far weaker than its data (1 in 58 million versus 1 in 78 trillion) and highly sensitive to rebuild delay. Tom's Hardware says the power math adds up but open, fair comparison is still needed.","sledRelevance":"Directly relevant to power-constrained university and state research data centers sizing multi-petabyte AI storage, such as TACC's Horizon or Georgia Tech's Nexus (both archived VAST deployments): drive size, power and rebuild risk are now procurement variables. It is a vendor claim with no independent validation, and has little relevance to K-12, local government or HHS buyers outside shared research or state data-center contexts.","evidence":"Read the full article and table. Cross-checked VAST's 2023 reliability white paper, whose methods note says absolute probability projections are not intended to be accurate, and a Sept 2026 LAD deck showing Lustre 2.18 adding read-only erasure coding, which complicates the 'double parity' baseline. StorageMath's independent analysis separately flags the same metadata-triplication weakness.","architectureImplications":"Larger SSDs cut power per petabyte but lengthen rebuilds; sites should model protection width, fault-domain size and metadata replication together rather than headline data-durability figures.","governanceImplications":"Durability figures are vendor-modelled; procurement teams should require stated assumptions (AFR, rebuild time, failure-domain layout) and treat cross-vendor odds as illustrative.","securityPrivacyImplications":"Not addressed; durability is distinct from security, but data-loss risk matters for research data retention obligations.","caveats":"Vendor simulation; VAST's scheme undisclosed; inputs not published; competitor characterisations are the presenter's; Tom's Hardware is reporting, not testing.","streamIds":["vast-data"],"roles":{"sales":"Framing: lead with power, not fear. VAST's SC26 argument is that petabyte SSDs will save research data centers megawatts, and that protection design must change to make them safe. For university research computing leaders this is a credible conversation about power and capacity planning. Do not quote 1 in 62 billion as fact; the scheme is undisclosed and VAST itself says metadata is the weak link. Offer a design review that puts drive size, power and rebuild assumptions on the table.","engineering":"Framing: check the assumptions behind the odds. The simulation used 7,920 x 122 TB SSDs in 180 enclosures and reported metadata risk far above data risk, with metadata rebuild starting about 12 seconds after a failure. Ask for the failure-rate and rebuild inputs, the failure-domain layout and how metadata replicas are placed. Compare against the customer's incumbent protection settings, noting Lustre 2.18 is adding erasure coding. Treat cross-vendor odds as illustrative, as VAST's own 2023 white paper does.","delivery":"Framing: rebuild speed becomes an operating metric. If metadata drive replacement delays carry outsized risk, delivery teams should define drive-failure runbooks, spares on site and alert escalation with the customer before go-live. Larger drives mean longer rebuilds, so plan monitoring of rebuild duration and degraded-mode behaviour. Any durability target written into acceptance criteria should be a proposal grounded in disclosed assumptions, not the vendor's simulated figure."},"roleDetails":{"sales":{"customerProblem":"Research data centers face power caps while storage needs grow to hundreds of petabytes, and lack neutral data on protection risk with very large SSDs.","stakeholders":["Research computing director","Data center facilities manager","University CIO","Storage architects","Procurement office"],"discoveryQuestions":["What power budget is reserved for storage over the next five years?","What drive sizes and protection schemes run today?","How quickly are failed drives replaced on site?","How are durability claims assessed in your RFPs?"],"valueHypothesis":"Interpretation: larger SSDs with wide erasure coding may lower storage power per petabyte; durability advantages are vendor-modelled and unverified.","potentialEngagement":"A storage power and resilience design review comparing current settings with large-drive options and documented assumptions.","unsupportedClaims":["VAST's 1 in 62 billion figure as a guarantee","Competitor systems will lose data at the simulated odds","Specific power savings for a given site"]},"engineering":{"fit":"Relevant to multi-petabyte flash systems at power-limited research sites; marginal for small deployments.","architectureIntegration":"Concerns the storage protection layer: erasure-coding width, failure-domain size, metadata replication and rebuild behaviour.","prerequisites":["Vendor failure-rate and rebuild-time assumptions","Site power budget","Incumbent protection configuration"],"constraints":["Undisclosed VAST scheme","Simulation not independently reproduced","Metadata triplication tolerates two failures"],"security":"Not a security claim; confirm durability features do not alter encryption or access-control behaviour.","proofOfValue":["Request the simulation inputs and rerun with site failure data","Fault-injection test of metadata drive loss in a pilot","Measure rebuild time for the proposed drive size"]},"delivery":{"work":"Define drive-failure runbooks, spares strategy and rebuild monitoring for large-SSD deployments.","dependencies":["On-site spares contract","Vendor support response times","Monitoring integration"],"ownership":"Research computing storage operations with facilities.","skillsAdoption":"Staff need to understand erasure-coding and rebuild behaviour and degraded-mode procedures.","governanceCheckpoints":["Design review of protection settings","Failure drill before production","Annual review of rebuild metrics"],"acceptanceCriteria":["Proposed: metadata drive failure handled within an agreed replacement window in a drill","Proposed: rebuild time for chosen drive size measured and documented"],"risks":["Over-quoting vendor durability odds","Slow drive replacement for metadata devices","Longer rebuild windows with larger drives"]}},"retrievedAt":"2026-11-20T22:16:44-06:00","enrichedAt":"2026-11-20T22:20:05-06:00","enrichmentBasis":"retrieved source","accessibilityWorkforceImplications":"Small research computing teams may lack staff to meet tight drive-replacement windows.","procurementImplications":"RFPs can require disclosed durability assumptions, metadata protection details and on-site spares terms rather than headline odds.","operatingModelImplications":"Drive-replacement speed becomes a contractual and staffing question, not only a hardware spec.","peerReview":"unknown","sourceVerification":{"openedUrl":"https://www.tomshardware.com/pc-components/ssds/vast-data-says-petabyte-ssds-will-outgrow-raid-in-todays-parallel-file-systems-simulation-of-a-900-pb-system-puts-data-loss-odds-at-1-in-11-over-10-years","referenceExcerpt":"while at least the power math adds up, data still needs to be compared openly and fairly to make a firm conclusion","promptVersion":"sled-research-v4.0","model":null,"basis":"agent-reported inspection"}}}]}