{"resourceId":"vast-lockwood-900pb-webinar-8008-ssds-20261209","versions":[{"version":"external-b869dd40004ce46969bca6abfac8382fbb7934f6b46f161d82a49cfe03a61c27","resource":{"id":"vast-lockwood-900pb-webinar-8008-ssds-20261209","title":"VAST webinar page (Dec 9, 2026): Lockwood to show a real 900 PB production system with 8,008 122 TB SSDs and simulated failure data","organization":"VAST Data","sector":"HPC and AI data centers; applicable to power-constrained university and research computing centers","geography":"Global","publishedAt":"Undated event page (webinar Dec 9, 2026)","publicationDate":null,"eventDate":"2026-12-09","sourceName":"VAST Data","sourceLabel":"Vendor event page","sourceUrl":"https://www.vastdata.com/events/900-petabytes-and-not-a-watt-more","evidenceClass":"vendor-claim","outcomeClass":"emerging","topics":["infrastructure","operating-model"],"finding":"VAST's event page for a Dec 9 webinar says Glenn Lockwood will use a real 900 PB system in production with 8,008 SSDs of 122 TB each to discuss what storage bandwidth costs in GPU power, potential savings from next-generation SSDs, ten years of simulated drive failures against that exact system, and failure detection and recovery across hundreds of servers. The production drive count (8,008) differs from the 7,920-drive configuration reported for VAST's SC26 simulation.","sledRelevance":"University and research data centers sizing large flash systems (e.g., TACC Horizon's 400 PB and NCSA Garnet's planned 50 PB raw VAST tier, both archived) are power-constrained; the webinar is a scheduled chance to question VAST's power and data-protection assumptions. Interpretation; no SLED data in the source.","evidence":"Read the event description and learning objectives. Compared drive counts with the archived Tom's Hardware SC26 report (7,920 SSDs, 180 enclosures of 44). No data or slides yet.","architectureImplications":"High-capacity SSDs trade bandwidth and rebuild time for capacity per watt; protection must scale with drive size.","governanceImplications":"Design reviews should ask vendors to reconcile modeled and production configurations before relying on simulated risk figures.","securityPrivacyImplications":"Not addressed beyond data-durability framing.","caveats":"Vendor marketing for a future event; customer unnamed; no publication date on the page; simulation results come from VAST, not an independent party; 8,008 vs 7,920 difference unexplained.","streamIds":["vast-data"],"roles":{"sales":"Framing: an invitation to ask hard questions, not proof. For research computing leaders weighing large flash tiers against power budgets, the Dec 9 session is a low-cost way to hear VAST's power and durability argument directly. Position it as education. Do not quote the simulated loss odds as guarantees, and acknowledge the production system is unnamed and its drive count differs from the modeled one.","engineering":"Framing: reconcile the numbers before using them. The page says the production system has 8,008 drives while SC26 coverage describes a 7,920-drive simulation; engineers should ask which configuration underlies each result, what failure data feeds the model, and how rebuild times scale for 122 TB and 245 TB drives. Treat simulated loss probabilities as vendor modeling until independently reproduced on a comparable public system.","delivery":"Framing: turn the webinar into a design checklist. Teams planning large flash tiers can capture VAST's stated assumptions on watts per SSD, bandwidth targets and parity schemes, then compare them with their own facility power limits and failure-handling procedures. Record which recovery behaviors (failure detection, rebuild coordination) are product features and which depend on site operations."},"roleDetails":{"sales":{"customerProblem":"Power-constrained research data centers must size petabyte flash tiers without starving GPUs of power or risking data loss on very large drives.","stakeholders":["Research computing director","Facilities and power planner","Storage architect","CIO"],"discoveryQuestions":["What is your storage power budget relative to GPU power?","What drive capacities are you planning for next refresh?","What parity scheme and rebuild window do you accept today?"],"valueHypothesis":"Interpretation: larger SSDs may free facility power for compute if data protection is designed for their rebuild times.","potentialEngagement":"A briefing session after the Dec 9 webinar comparing VAST's assumptions with the site's power and durability requirements.","unsupportedClaims":["Specific data-loss odds for any customer system","Power savings at a named SLED site","Identity or performance of the 900 PB system"]},"engineering":{"fit":"Large shared flash tiers at power-limited campuses and national research centers.","architectureIntegration":"VAST DASE with system-wide erasure coding on high-capacity QLC SSDs.","prerequisites":["Site power and cooling budget","Target bandwidth requirement","Failure-domain design"],"constraints":["Vendor modeling only","Production system unnamed","Rebuild time grows with drive capacity"],"security":"Not addressed.","proofOfValue":["Ask VAST to state which configuration (8,008 or 7,920 drives) each result uses","Request the failure-rate inputs to the simulation","Compare modeled rebuild times with observed rebuilds on an existing system"]},"delivery":{"work":"Capture webinar assumptions into the site's storage design review and power plan.","dependencies":["Webinar materials","Site power data","Vendor configuration details"],"ownership":"Storage architecture lead with facilities.","skillsAdoption":"Staff review erasure-coding and rebuild-time trade-offs for high-capacity drives.","governanceCheckpoints":["Design review comparing modeled and site-specific durability","Facilities sign-off on storage power budget"],"acceptanceCriteria":["Proposed: documented storage watts per usable PB for the chosen design","Proposed: documented rebuild-time estimate per drive size"],"risks":["Relying on unreproduced vendor simulations","Configuration mismatch between model and deployment"]}},"retrievedAt":"2026-11-26T22:17:05-06:00","enrichedAt":"2026-11-26T22:20:25-06:00","enrichmentBasis":"retrieved source","accessibilityWorkforceImplications":"No direct effect.","procurementImplications":"Request vendor durability modeling inputs and production references as part of large flash procurements.","operatingModelImplications":"Larger drives lengthen rebuilds; operations need monitored failure handling and clear escalation.","peerReview":"unknown","sourceVerification":{"openedUrl":"https://www.vastdata.com/events/900-petabytes-and-not-a-watt-more","referenceExcerpt":"we use a real 900 PB system, in production today with 8,008 SSDs of 122 TB each","promptVersion":"sled-research-v4.0","model":null,"basis":"agent-reported inspection"}}}]}