From the Utility Management edition of November 24, 2026
CISA warns that AutomationDirect C-More HMI programming software used in water and energy can be compromised by a malicious project file; fix is V6.81
U.S. Cybersecurity and Infrastructure Security Agency (CISA); vendor AutomationDirect · Water and wastewater and energy OT: HMI engineering software security · United States (deployed worldwide)
- Publisher
- CISA ICS Advisories
- Original publication
- 2026-11-24
- Source retrieved
- 2026-11-25
What happened
CISA reports a high-severity flaw in AutomationDirect C-More EA9 programming software up to V6.80: opening a crafted project file can corrupt memory and may allow code execution on the engineering workstation. Water and wastewater is a listed sector. A fixed version, V6.81, is available and no exploitation has been reported.
Why it matters
Released 24 November, the edition date. Small municipal water and wastewater systems commonly maintain HMI projects on engineering laptops and exchange project files with integrators, which is the delivery path described.
Evidence and measured results
Official advisory with affected versions, CVE, CVSS scores, sectors and vendor fix. No incident data.
Limitations and uncertainty
Severity depends on how workstations are used and segmented; no exploitation reported.
Put this evidence to work
Lighthouse Advisory interpretation, grounded in this source. Enriched 2026-11-24; this does not change the original publication date. Each role follows the same checklist so takeaways compare across sources.
Sales
Role takeaway
- Customer problem
- Small utilities rarely track patch levels of HMI engineering software or control project files from integrators.
- Stakeholders
- Operations or SCADA supervisor
- Utility IT lead
- System integrator
- Utility manager
- Discovery questions
- Which laptops have C-More programming software installed?
- How are HMI project files received from integrators?
- Who patches engineering software?
- Value hypothesis
- An engineering-software inventory and patch check may close a known file-based attack path quickly.
- Potential engagement
- OT engineering workstation inventory and patch review.
- Unsupported claims
- Active exploitation
- Exposure at a named utility
- Patching alone ensures security
Pre-sales engineering
Role takeaway
- Fit
- Utilities with AutomationDirect C-More HMIs.
- Architecture and integration
- Engineering workstations with HMI programming software, exchanging project files with integrators.
- Prerequisites
- Software inventory
- Vendor update V6.81
- File intake rule
- Constraints
- Contractor-owned laptops
- Legacy projects
- Limited OT staff
- Security
- Malicious project file can cause heap overflow and possible code execution; requires user to open it.
- Proof of value
- Version check on all workstations
- Test opening legacy projects after update
- Documented file intake path
Delivery
Role takeaway
- Work
- Update programming software and set rules for accepting HMI project files.
- Dependencies
- Inventory
- Integrator cooperation
- Change window
- Ownership
- SCADA or operations supervisor
- Skills and adoption
- Operators learn to verify file sources before opening.
- Governance checkpoints
- Advisory tracking log
- Patch confirmation
- Integrator contract clause
- Acceptance criteria
- All instances at V6.81
- File intake rule documented
- Contractor laptops verified
- Risks
- Unmanaged contractor laptops
- Reopened old files
- Missed installations
Implementation considerations
Lighthouse Advisory interpretation across the operating dimensions a public-sector buyer must settle before this evidence becomes a design. Each note answers the question under its heading for this specific source.
Architecture and integration
What must connect, and where does the AI sit in the workflow?
Risk sits on engineering workstations that open HMI project files from integrators, email or removable media.
Governance
Who approves, reviews and stays accountable for outcomes?
Patch tracking for engineering software and rules for accepting project files from third parties should be part of OT change control.
Security and privacy
What data, permissions and controls need testing?
Local code execution via malicious file; user interaction required; update to V6.81.
Accessibility and workforce
Who is affected, and what skills or accommodations follow?
Small systems often rely on one operator or an outside integrator to maintain HMI software.
Procurement
What should contracts, pricing and exit terms secure?
Integrator contracts should require supplying files from patched tools and through controlled channels.
Operating model
Which teams own the service once it runs?
Engineering workstation patching and file handling become routine OT maintenance tasks.
Publication history
- 2026-11-24Utility Management · Issue 266 resources
Stable resource ID: cisa-icsa-26-328-01-automationdirect-c-more-ea9-water-wastewater-2026