From the Utility Management edition of November 5, 2026
Freeland Municipal Authority puts a digital twin, leak loggers and AMI to work on non-revenue water
Freeland Municipal Authority (FMA) · Municipal drinking water utility, asset and leak management · Freeland, Pennsylvania (US)
- Publisher
- WaterWorld
- Original publication
- WaterWorld Top Projects, 2 Nov 2026
- Source retrieved
- 2026-11-06
What happened
Freeland Municipal Authority, serving about 3,900 residents through 2,100 connections, implemented a $225,033 digital twin integrating Bentley OpenFlows WaterSight with 74 acoustic leak loggers, 15 AMI smart meters, SCADA and other operational data, supported by a $203,500 Susquehanna River Basin Commission grant. Middleware translated incompatible legacy SCADA formats; staff relocated and calibrated loggers to reduce traffic and equipment noise. HRG provides monthly analytics reviews. The Authority reports reduced time, labor, fuel, chemical use and energy spent locating leaks, but no quantified water-loss reduction is published.
Why it matters
A small US municipal water utility showing digital-twin and AMI instrumentation can be grant-funded and operated with ongoing partner support is directly transferable to similarly sized SLED water systems facing non-revenue water and thin engineering benches.
Evidence and measured results
WaterWorld Top Projects feature dated 2 Nov 2026 based on utility and consulting-engineer accounts. Cost and grant figures are stated; leak-finding resource savings are qualitative. No before/after non-revenue-water percentage is given.
Limitations and uncertainty
Qualitative benefits only; vendor and consultant co-authored narrative risk; AMI coverage is still limited (15 meters).
Put this evidence to work
Lighthouse Advisory interpretation, grounded in this source. Enriched 2026-11-05; this does not change the original publication date. Each role follows the same checklist so takeaways compare across sources.
Sales
Role takeaway
- Customer problem
- Aging distribution leaks drive non-revenue water that is slow and costly to locate.
- Stakeholders
- Utility technical manager
- Consulting engineer
- SCADA/automation vendor
- Granting agency
- Discovery questions
- What is current non-revenue water?
- Are SCADA data formats documented?
- Is grant funding available for instrumentation?
- Value hypothesis
- Federating SCADA, AMI and acoustic loggers in a twin can shorten leak search; savings size is unmeasured here.
- Potential engagement
- Digital-twin readiness, middleware design and logger pilot.
- Unsupported claims
- A specific water-loss percentage reduction
- Zero field calibration effort
- Fit without SCADA normalisation
Pre-sales engineering
Role takeaway
- Fit
- Small to mid-size water utilities with some SCADA and willingness to add loggers/AMI.
- Architecture and integration
- WaterSight (or equivalent) plus middleware from SCADA/AMI/logger feeds into a calibrated hydraulic model.
- Prerequisites
- SCADA access
- Hydraulic model or willingness to build one
- Logger siting plan
- Constraints
- Legacy data formats
- Traffic/equipment acoustic noise
- Thin in-house analytics staff
- Security
- Treat middleware and twin as OT-adjacent; define accounts, logging and network paths before go-live.
- Proof of value
- Twin/logger flags vs confirmed finds
- False-positive rate per week
- Field-hours per confirmed leak
Delivery
Role takeaway
- Work
- Fund and install twin and sensors, build middleware, calibrate loggers, set monthly review.
- Dependencies
- Grant or capital
- Software vendor
- Field crews for logger moves
- Ownership
- Utility technical manager with consulting partner.
- Skills and adoption
- Train staff on twin navigation and logger maintenance.
- Governance checkpoints
- SCADA data-sharing approval
- Calibration acceptance
- Monthly analytics review
- Acceptance criteria
- Proposed: documented confirmed leaks found via system
- Proposed: capital list updated from twin views
- Proposed: middleware uptime/error log reviewed monthly
- Risks
- Acoustic false alarms
- SCADA mapping errors
- Partner dependency
Implementation considerations
Lighthouse Advisory interpretation across the operating dimensions a public-sector buyer must settle before this evidence becomes a design. Each note answers the question under its heading for this specific source.
Architecture and integration
What must connect, and where does the AI sit in the workflow?
Digital twin (WaterSight) federates AMI, acoustic loggers and SCADA via middleware that normalises legacy automation formats into a single hydraulic/operational view.
Governance
Who approves, reviews and stays accountable for outcomes?
Grant-backed capital plus monthly consultant validation turn a one-time install into a continuing asset-management program rather than a finished IT project.
Security and privacy
What data, permissions and controls need testing?
SCADA integration and middleware expand the OT-to-analytics path; the article does not describe segmentation, access control or logger data protection.
Accessibility and workforce
Who is affected, and what skills or accommodations follow?
Centralised view reduces field trips for leak search; staff learned logger calibration; monthly partner support fills specialised analytics capacity.
Procurement
What should contracts, pricing and exit terms secure?
$225k project with majority grant funding; middleware and field calibration were needed beyond software licences.
Operating model
Which teams own the service once it runs?
Shifts from reactive leak search toward continuous instrumentation, capital prioritisation, drought monitoring and PFAS-era planning using one data view.