From the Cisco edition of November 23, 2026
Shirudo's own Overhead documentation bounds its performance claims: figures come from one test VM with a software TPM, exclude BPF trampoline cost, and the runtime does not limit how much work a shield ('upatch') can add
Shirudo project (Cisco and OpenAI) · AI security infrastructure (Linux hosts) · Global
- Publisher
- shirudo docs (docs.shirudo.dev)
- Original publication
- Undated documentation page published with the Nov 23, 2026 open-source launch; retrieved 2026-11-24
- Source retrieved
- 2026-11-24
- Event date
- 2026-11-23
What happened
The project's Overhead page says all times and memory peaks come from one test VM (AMD Ryzen 9 3950X host, QEMU/KVM guest with 4 vCPUs and 4 GiB, pinned bpf-next kernel, software TPM swtpm 0.7.3) and show 'orders of magnitude for that system'. Hook times count each BPF program run but not the BPF trampoline around it. Background timers used 0.43 s of CPU per minute (0.71% of one vCPU) in that VM. The runtime limits neither how many programs and maps a shield brings nor how often the kernel runs them, and 'a badly written upatch can slow the target down or use much of its memory.'
Why it matters
Agencies considering agent-written shields need to know performance claims are lab-only and that a poorly generated shield can degrade production services. For SLED systems with uptime obligations (911-adjacent services, benefits portals, campus systems), that pushes testing onto the agency.
Evidence and measured results
Project documentation read in full, including the measurement-setup table and method notes. It is self-reported by the developers and is more candid than the launch announcements. No production, hardware-TPM or multi-host measurements.
Limitations and uncertainty
Undated page; developers' own documentation; single synthetic environment; does not evaluate shield correctness or false blocks.
Put this evidence to work
Lighthouse Advisory interpretation, grounded in this source. Enriched 2026-11-24; this does not change the original publication date. Each role follows the same checklist so takeaways compare across sources.
Sales
Role takeaway
- Customer problem
- Agencies need to know whether temporary AI-written protections will slow critical services; the only published figures come from one lab VM.
- Stakeholders
- Infrastructure operations lead
- Application owners of uptime-critical services
- CISO
- Performance and monitoring team
- Discovery questions
- Which services cannot tolerate added latency during an emergency mitigation?
- Do you have representative non-production hosts for performance testing?
- Do your hosts have hardware TPMs?
- How do you attribute performance regressions to a specific change today?
- Value hypothesis
- Bounded: an agency-run performance gate could catch costly shields before enforcement, reducing the risk of self-inflicted outages.
- Potential engagement
- A short test-harness build that measures shield overhead on the customer's representative hardware.
- Unsupported claims
- That Shirudo's overhead is negligible in production
- That figures from one VM transfer to agency hardware
- That the eBPF verifier prevents performance problems
Pre-sales engineering
Role takeaway
- Fit
- Agencies evaluating Shirudo or similar eBPF runtime mitigations on Linux.
- Architecture and integration
- Measurement uses kernel BPF statistics, systemd accounting and per-command timing; agencies would replicate on their own kernels and TPMs.
- Prerequisites
- Representative test hosts
- kernel.bpf_stats_enabled access
- Baseline service performance metrics
- Constraints
- Trampoline overhead not measured in docs
- Software TPM in tests
- No limit on shield resource use
- Security
- Enforce resource thresholds operationally; monitor for shield-attributable slowdowns; keep a rapid unload path.
- Proof of value
- Measure per-shield CPU and latency on target hardware
- Include trampoline cost
- Test hooks on high-frequency syscalls
- Confirm unload restores baseline
Delivery
Role takeaway
- Work
- Build and run a reusable shield performance gate.
- Dependencies
- Platform engineering
- Monitoring/observability team
- Application owners
- Ownership
- Platform engineering owns the gate; application owners set thresholds.
- Skills and adoption
- Staff need to run BPF statistics and interpret per-hook overhead.
- Governance checkpoints
- Thresholds agreed per service
- Gate results recorded before enforcement
- Exceptions approved by CISO
- Acceptance criteria
- Proposed: no enforced shield exceeds the agreed CPU or latency threshold
- Proposed: performance gate completes within a defined time target during an urgent disclosure
- Risks
- Gate delays urgent mitigation
- Lab results miss production load patterns
- Shield degrades a critical service
Implementation considerations
Lighthouse Advisory interpretation across the operating dimensions a public-sector buyer must settle before this evidence becomes a design. Each note answers the question under its heading for this specific source.
Architecture and integration
What must connect, and where does the AI sit in the workflow?
Overhead depends on the hooks a shield attaches to (hooks on every open or exec are costly) and on the host's CPU, kernel, disk and TPM. Hardware TPMs answer more slowly than the software TPM used in testing.
Governance
Who approves, reviews and stays accountable for outcomes?
Acceptance criteria for any shield should include performance limits measured on the agency's own hardware, because the runtime does not enforce any.
Security and privacy
What data, permissions and controls need testing?
A resource-hungry shield could act as a self-inflicted denial of service on a protected host. The verifier bounds a single program run, not cumulative cost.
Accessibility and workforce
Who is affected, and what skills or accommodations follow?
Interpreting these figures and writing performance tests needs kernel-level skills that small SLED teams rarely have.
Procurement
What should contracts, pricing and exit terms secure?
Any commercial offering built on Shirudo should come with performance guarantees or test results on representative hardware.
Operating model
Which teams own the service once it runs?
Performance testing becomes a required gate before a shield is enforced, adding time to the very window the tool aims to shorten.
Publication history
- 2026-11-23Cisco · Issue 226 resources
Stable resource ID: shirudo-overhead-docs-single-test-vm-unbounded-upatch-cost-20261123