Lighthouse AdvisorySLED AI Adoption Intelligence
← Back to results

From the Research Universities edition of November 25, 2026

Academic researchCautionaryPreprint, not peer reviewedNew this fortnight

Griffith University preprint: multiplying a 'typical' energy-per-query figure by visible prompts underestimates a university's AI inference electricity about 3.4 times today and about 15 times in a 2030 scenario; agent workflows drive the growth

Griffith University, Australia (Nathan A. Garland, Ryan F. Heneghan) · Research enterprise and university operations: AI inference electricity, emissions accounting and sustainability reporting · Australia (Australian public universities case study); method transferable to U.S. institutions with local inputs

Publisher
arXiv (Garland and Heneghan, Griffith University)
Original publication
Submitted to arXiv 24 November 2026 (arXiv 2611.31960, v1, cs.CY); appeared in the cs.CY new listing of Wednesday 25 November 2026
Source retrieved
2026-11-26
Read original source

What happened

Preprint, not peer reviewed; a modelling study, not measured consumption. The authors' open SULLEE model links token counts, serving hardware and workflow structure to annual institutional electricity, with Monte Carlo uncertainty. Multiplying one 'typical' per-query energy figure by visible user prompts misses two things: energy per task is right-skewed, and each visible prompt can trigger more agent and tool calls. Together these imply an underestimate of about 3.4 times under present-day observed use, rising to about 15 times in a 2030 high-integration scenario. The highest-energy 10% of requests account for about 60% of modelled inference electricity. For a representative 20,000-student Australian university, mean annual AI inference electricity rises from 17.3 MWh (P05-P95 3.1-47.1) under 2026 observed use to up to 287.4 MWh (41.5-830.7) by 2030. Conventional chat is about 87% of modelled electricity in 2026 but about 20% in the 2030 scenario, while agent workflows rise from about 8% to about 78%. The authors note that Monte Carlo sampling of declared priors is not a measured population distribution. Included because it is new (24 Nov) and gives universities a method for AI emissions reporting as agent use grows.

Why it matters

Relevant to universities buying enterprise AI services and reporting Scope 3 emissions: it shows per-query figures used in sustainability claims can understate demand several-fold, mostly because of agent workflows. Figures are modelled for Australian universities; U.S. transfer needs local usage, hardware and grid data.

Evidence and measured results

Single modelling preprint; abstract, highlights, context, model description, scenario results and Scope 3 discussion read. Outputs depend on assumed hardware, task mix (for example user chat 20-40% of requests) and uptake scenarios; no metered institutional data validate the totals.

Limitations and uncertainty

Preprint; modelled, not metered; Australian case; assumptions on hardware, task mix and uptake drive results; wide uncertainty ranges.

Put this evidence to work

Lighthouse Advisory interpretation, grounded in this source. Enriched 2026-11-25; this does not change the original publication date. Each role follows the same checklist so takeaways compare across sources.

Sales

Role takeaway
Customer problem
Universities reporting AI-related emissions may rely on per-query figures that understate demand as agent use grows.
Stakeholders
  • Chief sustainability officer
  • CIO
  • Facilities and energy manager
  • Procurement lead
Discovery questions
  • How do you estimate AI electricity or emissions today?
  • Can you see token and agent-call data from your AI services?
  • Do vendors give you per-workflow energy data?
  • Is AI in your Scope 3 reporting?
Value hypothesis
Workflow-aware estimates may give more defensible AI emissions reporting; shown only in a modelled Australian case.
Potential engagement
A short assessment of AI usage telemetry and a pilot workflow-aware energy estimate for one academic year.
Unsupported claims
  • Measured campus electricity totals
  • U.S. figures without local inputs
  • Emissions reductions from any action
  • Guaranteed savings

Pre-sales engineering

Role takeaway
Fit
Fits institutions running an AI gateway or enterprise AI licences with access to usage logs.
Architecture and integration
Gateway or vendor logs of tokens, model and tool calls per request feed an open bottom-up energy model with Monte Carlo uncertainty.
Prerequisites
  • Token-level usage logs
  • Model and hardware assumptions
  • Local grid emissions factors
  • Uptake scenarios
Constraints
  • Modelled not metered
  • Australian case
  • Vendor hardware data often unavailable
  • Wide uncertainty ranges
Security
Usage telemetry should be aggregated and stripped of user content before modelling; not addressed by the paper.
Proof of value
  • Compare per-query and workflow-aware estimates on local logs
  • Test sensitivity to hardware and task-mix assumptions
  • Check against any vendor-provided energy data

Delivery

Role takeaway
Work
Collect AI usage telemetry, run a workflow-aware energy estimate and integrate results into sustainability reporting.
Dependencies
  • Access to gateway or vendor logs
  • Sustainability office input
  • Grid emissions data
  • Analyst time
Ownership
The sustainability office owns reporting; IT owns usage telemetry and the AI gateway.
Skills and adoption
Sustainability analysts learn token-based accounting; IT staff learn to expose workflow fan-out metrics.
Governance checkpoints
  • Approval of telemetry collection scope
  • Review of assumptions before publication
  • Annual update of uptake scenarios
Acceptance criteria
  • Proposed: estimate reported with uncertainty range
  • Proposed: agent-call share of traffic measured
  • Proposed: comparison with per-query method documented
Risks
  • Assumptions dominating results
  • Incomplete vendor data
  • Misreading modelled totals as measured
  • Privacy concerns over logs

Implementation considerations

Lighthouse Advisory interpretation across the operating dimensions a public-sector buyer must settle before this evidence becomes a design. Each note answers the question under its heading for this specific source.

Architecture and integration

What must connect, and where does the AI sit in the workflow?

Agent and tool-call context dominates future inference energy; architecture choices that shrink context and tool loops matter more than chat volume.

Governance

Who approves, reviews and stays accountable for outcomes?

Sustainability reporting on AI should use task-level, workflow-aware estimates with uncertainty ranges, not a single per-query figure.

Security and privacy

What data, permissions and controls need testing?

Not discussed; the model needs aggregate usage telemetry, which institutions would collect from vendor or gateway logs.

Accessibility and workforce

Who is affected, and what skills or accommodations follow?

Sustainability and IT staff need skills to gather token and workflow data and run uncertainty models.

Procurement

What should contracts, pricing and exit terms secure?

Institutions could ask AI vendors for token, model and hardware data per workflow to support Scope 3 reporting; vendor 'typical query' figures may mislead.

Operating model

Which teams own the service once it runs?

Energy accounting must track agent calls behind each visible prompt, which shifts responsibility toward gateway and platform owners who see that traffic.

Publication history

  1. 2026-11-25Research Universities · Issue 783 resources
Read preserved resource versions (JSON)

Stable resource ID: arxiv-2611-31960-typical-query-energy-underestimates-university-ai-electricity-sullee-20261124