Tom's Hardware: VAST's SC26 simulation says enclosure-local RAID fails with petabyte SSDs; VAST concedes its triplicated metadata is the weakest link
VAST Data (presenter) / Tom's Hardware (reporting) · Research computing and large-scale AI storage (vendor technical claim) · United States (SC26, Chicago); applies globally
- Publisher
- Tom's Hardware
- Original publication
- 2026-11-20
- Source retrieved
- 2026-11-21
What happened
At SC26 VAST presented a simulation of a 900 PB flash system arguing that petabyte-class SSDs will make enclosure-local declustered RAID unsafe (1 in 11 odds of data loss over 10 years) and that system-wide erasure coding with at least three parity strips is the minimum; VAST claims about 1 in 62 billion for its own undisclosed scheme. The same talk concedes VAST's three-copy metadata is far weaker than its data (1 in 58 million versus 1 in 78 trillion) and highly sensitive to rebuild delay. Tom's Hardware says the power math adds up but open, fair comparison is still needed.
Why it matters
Directly relevant to power-constrained university and state research data centers sizing multi-petabyte AI storage, such as TACC's Horizon or Georgia Tech's Nexus (both archived VAST deployments): drive size, power and rebuild risk are now procurement variables. It is a vendor claim with no independent validation, and has little relevance to K-12, local government or HHS buyers outside shared research or state data-center contexts.
Evidence and measured results
Read the full article and table. Cross-checked VAST's 2023 reliability white paper, whose methods note says absolute probability projections are not intended to be accurate, and a Sept 2026 LAD deck showing Lustre 2.18 adding read-only erasure coding, which complicates the 'double parity' baseline. StorageMath's independent analysis separately flags the same metadata-triplication weakness.
Limitations and uncertainty
Vendor simulation; VAST's scheme undisclosed; inputs not published; competitor characterisations are the presenter's; Tom's Hardware is reporting, not testing.
Put this evidence to work
Lighthouse Advisory interpretation, grounded in this source. Enriched 2026-11-20; this does not change the original publication date. Each role follows the same checklist so takeaways compare across sources.
Sales
Role takeaway
- Customer problem
- Research data centers face power caps while storage needs grow to hundreds of petabytes, and lack neutral data on protection risk with very large SSDs.
- Stakeholders
- Research computing director
- Data center facilities manager
- University CIO
- Storage architects
- Procurement office
- Discovery questions
- What power budget is reserved for storage over the next five years?
- What drive sizes and protection schemes run today?
- How quickly are failed drives replaced on site?
- How are durability claims assessed in your RFPs?
- Value hypothesis
- Interpretation: larger SSDs with wide erasure coding may lower storage power per petabyte; durability advantages are vendor-modelled and unverified.
- Potential engagement
- A storage power and resilience design review comparing current settings with large-drive options and documented assumptions.
- Unsupported claims
- VAST's 1 in 62 billion figure as a guarantee
- Competitor systems will lose data at the simulated odds
- Specific power savings for a given site
Pre-sales engineering
Role takeaway
- Fit
- Relevant to multi-petabyte flash systems at power-limited research sites; marginal for small deployments.
- Architecture and integration
- Concerns the storage protection layer: erasure-coding width, failure-domain size, metadata replication and rebuild behaviour.
- Prerequisites
- Vendor failure-rate and rebuild-time assumptions
- Site power budget
- Incumbent protection configuration
- Constraints
- Undisclosed VAST scheme
- Simulation not independently reproduced
- Metadata triplication tolerates two failures
- Security
- Not a security claim; confirm durability features do not alter encryption or access-control behaviour.
- Proof of value
- Request the simulation inputs and rerun with site failure data
- Fault-injection test of metadata drive loss in a pilot
- Measure rebuild time for the proposed drive size
Delivery
Role takeaway
- Work
- Define drive-failure runbooks, spares strategy and rebuild monitoring for large-SSD deployments.
- Dependencies
- On-site spares contract
- Vendor support response times
- Monitoring integration
- Ownership
- Research computing storage operations with facilities.
- Skills and adoption
- Staff need to understand erasure-coding and rebuild behaviour and degraded-mode procedures.
- Governance checkpoints
- Design review of protection settings
- Failure drill before production
- Annual review of rebuild metrics
- Acceptance criteria
- Proposed: metadata drive failure handled within an agreed replacement window in a drill
- Proposed: rebuild time for chosen drive size measured and documented
- Risks
- Over-quoting vendor durability odds
- Slow drive replacement for metadata devices
- Longer rebuild windows with larger drives
Implementation considerations
Lighthouse Advisory interpretation across the operating dimensions a public-sector buyer must settle before this evidence becomes a design. Each note answers the question under its heading for this specific source.
Architecture and integration
What must connect, and where does the AI sit in the workflow?
Larger SSDs cut power per petabyte but lengthen rebuilds; sites should model protection width, fault-domain size and metadata replication together rather than headline data-durability figures.
Governance
Who approves, reviews and stays accountable for outcomes?
Durability figures are vendor-modelled; procurement teams should require stated assumptions (AFR, rebuild time, failure-domain layout) and treat cross-vendor odds as illustrative.
Security and privacy
What data, permissions and controls need testing?
Not addressed; durability is distinct from security, but data-loss risk matters for research data retention obligations.
Accessibility and workforce
Who is affected, and what skills or accommodations follow?
Small research computing teams may lack staff to meet tight drive-replacement windows.
Procurement
What should contracts, pricing and exit terms secure?
RFPs can require disclosed durability assumptions, metadata protection details and on-site spares terms rather than headline odds.
Operating model
Which teams own the service once it runs?
Drive-replacement speed becomes a contractual and staffing question, not only a hardware spec.
Publication history
- 2026-11-20VAST Data · Issue 133 resources